MR-J4 AL.47 — Cooling fan error
Trip — immediate stop
CAUSE
Why does it occur?
- - The speed of the servo amplifier cooling fan decreased. - Or the fan speed decreased to the alarm occurrence level or less. Detail No. Detail name Cause Check method Check result Action Target 47.1 Cooling fan stop error (
- Foreign matter was caught in the cooling fan. Check if a foreign matter is caught in the cooling fan. Something has been caught. Remove the foreign matter. [A] [B] [WB] [RJ0
REMEDY · Step by step
How to fix it?
Replace the cooling fan
Do not reset repeatedly before identifying the cause. Repeated resets while ignoring a trip/alarm can cause secondary damage (IGBT failure, motor winding damage, etc.).