MR-J4 AL.33 — Overvoltage
Trip — immediate stop
CAUSE
Why does it occur?
- - The value of the bus voltage exceeded the prescribed value. 200 V class: 400 V DC 400 V class: 800 V DC 100 V class: 400 V DC 48 V DC setting: 75 V DC 24 V DC setting: 55 V DC Detail No. Detail name Cause Check method Check result Action Target 33.1 Main circuit voltage error (
- The setting of the regenerative resistor (regenerative option) is incorrect. Check the regenerative resistor (regener
REMEDY · Step by step
How to fix it?
Extend the deceleration time and add a regenerative resistor
Do not reset repeatedly before identifying the cause. Repeated resets while ignoring a trip/alarm can cause secondary damage (IGBT failure, motor winding damage, etc.).
SOURCE
Related manual page
Summary based on the official Mitsubishi Electric manual. For accurate and complete information, always consult the official manual.