MR-J4 AL.92 — Battery cable disconnection warning
Trip — immediate stop· AUTO-RESET
CAUSE
Why does it occur?
- - Battery voltage for absolute position detection system decreased. Detail No. Detail name Cause Check method Check result Action Target 92.1 Encoder battery cable disconnection warning (
- When an MR- BAT6V1SET(-A) battery or MR- BT6VCASE battery case was used, the battery was not connected to CN
- When an MR- BAT6V1BJ battery for junction battery cable was used, the battery was not connect
REMEDY · Step by step
How to fix it?
Check the cooling environment and load ratio.
Do not reset repeatedly before identifying the cause. Repeated resets while ignoring a trip/alarm can cause secondary damage (IGBT failure, motor winding damage, etc.).