FR-A800 E.OD — Position fault
Trip — immediate stop
CAUSE
Why does it occur?
- The inverter output is shut off when the difference between the position command and position feedback exceeds the setting of Pr.427 Excessive level error during position control
- This protective function is not available in the initial status. • Check that the position detecting encoder mounting or
REMEDY · Step by step
How to fix it?
- • Check the parameters. • Reduce the load. • Set Pr.427 and Pr.369 (Pr.8
- correctly.
Do not reset repeatedly before identifying the cause. Repeated resets while ignoring a trip/alarm can cause secondary damage (IGBT failure, motor winding damage, etc.).