FR-F800 E.PID — E.PID
Trip — immediate stop
CAUSE
Why does it occur?
- The inverter trips if the measured value exceeds the PID upper limit or PID lower limit parameter setting, or the absolute deviation value exceeds the PID deviation parameter setting during PID control
- Set this function in Pr
- 131 "PID upper limit", Pr
- 132 "PID lower limit", Pr
- 553 "PID deviation limit", and Pr
- 554 "PID signal operation selection". (Refer to page 5-347.) The inverter trips whe
REMEDY · Step by step
How to fix it?
Check that the meter has no failure or break. Set the parameters correctly.
Do not reset repeatedly before identifying the cause. Repeated resets while ignoring a trip/alarm can cause secondary damage (IGBT failure, motor winding damage, etc.).