InverterFR-E800Verification pending — cross-check with the official manual
FR-E800 LP — LP
Alarm — operational, inspection needed
CAUSE
Why does it occur?
- Appears when the Forward stroke end (LSP) signal or the Reverse stroke end (LSN) signal is assigned to the input terminal and the signal is turned OFF (normally closed input)
- The indication remains displayed while the signal is OFF
- Check if the LSP/LSN signal is turned OFF (normally closed input)
REMEDY · Step by step
How to fix it?
- Turn ON the LSP/LSN signal (normally closed input)
- Reference manual FR-E800 Instruction Manual (Function)
Do not reset repeatedly before identifying the cause. Repeated resets while ignoring a trip/alarm can cause secondary damage (IGBT failure, motor winding damage, etc.).