FR-E800 OLV — OLV
Alarm — operational, inspection needed
CAUSE
Why does it occur?
- • When the output voltage of the inverter increases, the stall prevention (overvoltage) function is activated. • The regeneration avoidance function is activated due to excessive regenerative power of the motor. • The following section explains about the stall prevention (overvoltage) function
- During deceleration If the regenerative power of the motor becomes excessive to exceed the regenerative
REMEDY · Step by step
How to fix it?
- The deceleration time may change
- Increase the deceleration time using Pr.8 Deceleration time
- Reference manual FR-E800 Instruction Manual (Function)
Do not reset repeatedly before identifying the cause. Repeated resets while ignoring a trip/alarm can cause secondary damage (IGBT failure, motor winding damage, etc.).