MR-JE AL.8E — USB/Serial/Modbus RTU Communication Error
Trip — immediate stop
CAUSE
Why does it occur?
- Communication error between servo amplifier and PC or controller via USB, serial, or Modbus RTU
- Eight sub-codes cover: receive error (8E.1), checksum error (8E.2), character error (8E.3), command error (8E.4), data number error (8E.5), Modbus receive error (8E.6), Modbus frame error (8E.7), Modbus CRC error (8E.8)
REMEDY · Step by step
How to fix it?
- Verify communication settings on PC/controller (protocol selection, baud rate, parity, station number)
- Inspect and replace communication cable if faulty
- Ensure transmitted data conforms to the specified communication protocol
- Replace servo amplifier if fault persists after confirming correct settings and cable
Do not reset repeatedly before identifying the cause. Repeated resets while ignoring a trip/alarm can cause secondary damage (IGBT failure, motor winding damage, etc.).